4.5 Article

Expanding Hydrophobically Modified Chitosan Foam for Internal Surgical Hemostasis: Safety Evaluation in a Murine Model

期刊

JOURNAL OF SURGICAL RESEARCH
卷 239, 期 -, 页码 269-277

出版社

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.jss.2019.01.060

关键词

Chitosan; Foam; Fibrin sealant; Hemostasis; Biodegradation; in vivo study

类别

资金

  1. National Science Foundation, United States (SBIR Award) [1256477]
  2. National Science Foundation, United States (SECO Supplemental Award)
  3. Directorate For Engineering [1256477] Funding Source: National Science Foundation
  4. Div Of Industrial Innovation & Partnersh [1256477] Funding Source: National Science Foundation

向作者/读者索取更多资源

Background: A novel injectable expanding foam based on hydrophobically modified chitosan (HM-CS) was developed to improve hemostasis during surgeries. HM-CS is an amphiphilic derivative of the natural biopolymer chitosan (CS); HM-CS has been shown to improve the natural hemostatic characteristics of CS, but its internal safety has not been systematically evaluated. The goal of this study was to compare the long-term in vivo safety of HM-CS relative to a commonly used fibrin sealant (FS), TISSEEL (Baxter). Methods: Sixty-four Sprague-Dawley rats (275-325 g obtained from Charles River Laboratories) were randomly assigned to control (n = 16) or experimental (n = 48) groups. Samples of the test materials (HM-CS [n = 16], CS [n = 16], and FS [n = 16]) applied to a nonlethal liver excision (0.4 +/- 0.3 g of the medial lobe) in rats were left inside the abdomen to degrade. Animals were observed daily for signs of morbidity and mortality. Surviving animals were sacrificed at 1 and 6 wk; the explanted injury sites were microscopically assessed. Results: All animals (64/64) survived both the 1- and 6-wk time points without signs of morbidity. Histological examination showed a comparable pattern of degradation for the various test materials. FS remnants and significant adhesions to neighboring tissues were observed at 6 wk. Residual CS and HM-CS were observed at the 6 wk with fatty deposits at the site of injury. Minimal adhesions were observed for CS and HM-CS. Conclusions: The internal safety observed in the HM-CS test group after abdominal implantation indicates that injectable HM-CS expanding foam may be an appropriate internal use hemostatic candidate. (C) 2019 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据