4.5 Article

Evaluation of a shape memory implant abutment system: An up to 6-month pilot clinical study

期刊

JOURNAL OF PROSTHETIC DENTISTRY
卷 123, 期 2, 页码 257-263

出版社

MOSBY-ELSEVIER
DOI: 10.1016/j.prosdent.2018.11.012

关键词

-

向作者/读者索取更多资源

Statement of problem. Screw- and cement-based retention mechanisms are used to attach prostheses to dental implants; however, each approach can lead to clinical complications such as crown fracturing or peri-implantitis. A novel abutment and prosthesis retention system has been engineered to achieve the esthetics and retention force of cement-based fixation while maintaining the retrievability of screw-retained restorations. Purpose. The purpose of this pilot clinical study was to evaluate the effectiveness of this innovative retention system on posterior tooth restorations. Material and methods. This clinical study, with up to 6 months of follow-up, included 8 participants with posterior osseointegrated implants who met the eligibility criteria to receive the abutment and shape memory sleeve. Radiographs were used to evaluate crown seating. Crown stability was measured using the Periotest, and occlusal analysis was performed using the Tekscan system and shimstock. Peri-implant health was evaluated by probing, and the plaque and gingival indices were recorded. In addition, patient-reported outcomes were recorded. Results. Minimal differences were observed between baseline and endpoint assessment of the plaque and gingival indices, probing depth, and proximal and occlusal contacts. There were no patient-reported problems or complaints about discomfort. The overall peri-implant health remained unchanged from the baseline evaluations for all participants. Proximal contact around the restoration was present at the baseline and at the conclusion of the study for 7 of the participants. Occlusal contact was observed to be either light (5 participants) or holding (3 participants). In addition, visual inspection of retrieved crowns revealed clean surfaces free of macroparticle ingress, and bacterial accumulation at the coping-abutment interface was not detected. Conclusions. The safety and efficacy findings of this pilot clinical study suggest that this new shape memory alloy-based retention system may provide a suitable alternative for implant prosthodontics. The retention system allowed for easy prosthesis seating and retrieval.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据