4.7 Article

Downstream radiative and convective heating from methane and propane fires with cross wind

期刊

COMBUSTION AND FLAME
卷 204, 期 -, 页码 1-12

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.combustflame.2019.03.001

关键词

Flame spread; Downstream heating; Cross wind; Flame attachment

资金

  1. National Natural Science Foundation of China [51636008]
  2. Key Research Program of the Chinese Academy of Sciences [QYZDB-SSW-JSC029]
  3. Fundamental Research Funds for the Central Universities [WK2320000035]
  4. USDA Forest Service Missoula Fire Sciences Laboratory through the National Fire Decision Support Center [18-CS-1121637-095]
  5. National Science Foundation [CBET 1554026]

向作者/读者索取更多资源

Experiments were conducted to elucidate the radiative and convective heating occurring downstream of wind-driven fires produced by a gaseous burner. These flames model, at reduced scale, some of the dynamics observed in wind-driven fire spread through wildlands, buildings, mines or tunnels. Methane and propane were used to create fires ranging from 5 to 25 kW with ambient velocities ranging from 0.6 to 2.2 m/s. The total and incident radiative heat flux to a nearly-adiabatic downstream surface were measured by a water-cooled total heat flux gauge and a radiometer, respectively. The interaction between the buoyancy induced by the flame and momentum from the free stream was represented by a mixed convection parameter xi = Gr(x2)/Re-x1(n) where n=3/2, 2 or 5/2. xi was evaluated with two length scales in order to capture effects of both the boundary layer development length (xi) and heated distance downstream of the burner (x(2)). Results showed that the propane flame (high luminosity) exhibited slightly higher radiative heat fluxes than methane flames (low luminosity) under the same external conditions, while the convective heat flux followed an opposite trend. The downstream local radiative heat flux was quantified using a dimensionless flame thickness delta(*)(x), which showed a good relationship with xi for n=5/2 but not 3/2 or 2. The local convective heat transfer coefficient was expressed in the form of a local Nusselt number, Nu(x2)Re(x1)(-1/2), and correlated well as a piecewise function with xi for n=5/2. It was found that both delta(*)(x) and Nu(x2)Re(x1)(-1/2) have a turning point at xi approximate to 0.005, which was visually shown to denote the location where transition between an attachment and plume-like flame occurs. By separately describing both radiative and convective downstream heating, the mechanisms controlling heating which drives flame spread in wind-driven fires can be further understood. (C) 2019 The Combustion Institute. Published by Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据