TIME AND FREQUENCY CHARACTERISTICS OF CAVITATION ACTIVITY ENHANCED BY FLOWING PHASE-SHIFT NANODROPLETS AND LIPID-SHELLED MICROBUBBLES DURING FOCUSED ULTRASOUND EXPOSURES

期刊

ULTRASOUND IN MEDICINE AND BIOLOGY
卷 45, 期 8, 页码 2118-2132

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.ultrasmedbio.2019.04.024

关键词

Dynamic cavitation; Focused ultrasound; Flowing lipid-shelled microbubbles; Flowing phase-shift nanodroplets

资金

  1. National Natural Science Foundation of China [11874297, 81827801]
  2. China Postdoctoral Science Foundation [2016 M600775]
  3. Postdoctoral Science Foundation [2016 BSHYDZZ25]

向作者/读者索取更多资源

This study investigated and compared the time and frequency characteristics of cavitation activity between phase-shift nanodroplets (NDs) and lipid-shelled microbubbles (MBs) exposed to focused ultrasound (FUS) under physiologically relevant flow conditions. Root-mean-square (RMS) of broadband noise, spectro-grams of the passive cavitation detection signals and inertial cavitation doses (ICDs) were calculated during FUS at varying mean flow velocities and two different peak-rarefactional pressures. At a lower pressure of 0.94 MPa, the mean values of the RMS amplitudes versus time for the NDs showed an upward trend but slowed down as the mean flow velocity increased. For flowing NDs, the rate of growth in RMS amplitudes within 2-5 MHz decreased more obviously than those within 5-8 MHz. At a higher pressure of 1.07 MPa, the increase in RMS amplitudes was accelerated as the mean flow velocity increased from 0 to 10 cm/s and slowed down as the mean flow velocity reached 15 cm/s. The general downward trends of RMS amplitudes for the MBs were retarded as the mean flow velocity increased at both acoustic pressures of 0.94 MPa and 1.07 MPa. At 0.94 MPa, the mean ICD value for the NDs decreased from 57 to 36 as the mean flow velocity increased from 0 to 20 cm/s. At 1.07 MPa, the mean ICD value initially increased from 45 to 57 as the mean flow velocity increased from 0 to 10 cm/s and subsequently decreased to 43 as the mean flow velocity reached 20 cm/s. For the MBs, the mean ICD value increased with increasing mean flow velocity at both acoustic pressures. These results could aid in future investigations of cavitation-enhanced FUS with the flowing phase-shift NDs and encapsulated, gas-filled MBs for various applications. (C) 2019 World Federation for Ultrasound in Medicine & Biology. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据