4.3 Article

Validation of self-reported occupational noise exposure in participants of a French case-control study on acoustic neuroma

出版社

SPRINGER
DOI: 10.1007/s00420-019-01427-2

关键词

Occupational self-reported noise exposure; Data validity; Exposure misclassification; Recall bias; Expert assessment; Case-control study

资金

  1. French Agency for Food, Environmental and Occupational Health & Safety (ANSES) 'Programme national de recherche Environnement-Sante Travail' [EST 11-74]
  2. European Fifth Framework Program, 'Quality of Life and Management of Living Resources' [QLK4-CT-1999901563]
  3. International Union against Cancer (UICC)
  4. Mobile Manufacturers' Forum
  5. GSM Association
  6. l'Association pour la Recherche sur le Cancer (ARC) [5142]
  7. Orange
  8. SFR
  9. Bouygues Telecom
  10. UICC

向作者/读者索取更多资源

Objectives To validate self-reported occupational loud noise exposure against expert evaluation of noise levels in a French case-control study on acoustic neuroma and to estimate the impact of exposure misclassification on risk estimation. Methods Noise levels were evaluated in 1006 jobs held by 111 cases and 217 population controls by an expert. Case-control differences in self-reporting were analyzed with logistic models. Sensitivity, specificity, positive and negative predictive values, and observed agreement of the self-reports were computed relative to the expert evaluation. They were used to calibrate the odds ratio (OR) between lifetime ever occupational loud noise exposure and the risk of acoustic neuroma, without adjustment for measurement error of the expert assessments. Results Cases reported noise levels in individual jobs closer to the expert assessment than controls, but the case-control difference was small for lifetime exposures. For expert-rated exposure of 80 dB(A), reporting of individual jobs by cases was more sensitive (54% in cases, 37% in controls), whereas specificity (91% in cases, 93% in controls) and observed agreement (82% in cases, 81% in controls) were similar. When lifetime exposure was considered, sensitivity increased (76% in cases, 65% in controls), while cases specificity decreased (84%). When these values were used to calibrate self-reports for exposure misclassification compared to expert evaluation at 80 dB(A), the crude OR of 1.7 was reduced to 1.3. Conclusions Despite the relatively accurate reporting of loud noise, the impact of the calibration on the OR was non-negligible.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据