4.2 Article Proceedings Paper

Quality control project of NGS HLA genotyping for the 17th International HLA and Immunogenetics Workshop

期刊

HUMAN IMMUNOLOGY
卷 80, 期 4, 页码 228-236

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.humimm.2019.01.009

关键词

NGS HLA typing; Proficiency testing; Reference cell panel; Quality control

资金

  1. Stanford Blood Center
  2. U.S. National Institutes of Health (NIH) National Institute of Neurological Disorders and Stroke (NINDS) [U19NS095774]
  3. NIH National Institute of Allergy and Infectious Disease (NIAID) [R01AI28775]
  4. Henry M. Jackson Foundation for the Advancement of Military Medicine, Inc. [W81XWH-07-2-0067]
  5. U.S. Department of Defense (DOD) [W81XWH-07-2-0067]
  6. Kuwait Foundation for Advancement of Science (KFAS) [2012-130-204]
  7. Genome Canada Genome Innovation Node grant [244819]
  8. [RVO: 61989592]

向作者/读者索取更多资源

The 17th International HLA and Immunogenetics Workshop (IHIW) organizers conducted a Pilot Study (PS) in which 13 laboratories (15 groups) participated to assess the performance of the various sequencing library preparation protocols, NGS platforms and software in use prior to the workshop. The organizers sent 50 cell lines to each of the 15 groups, scored the 15 independently generated sets of NGS HLA genotyping data, and generated consensus HLA genotypes for each of the 50 cell lines. Proficiency Testing (PT) was subsequently organized using four sets of 24 cell lines, selected from 48 of 50 PS cell lines, to validate the quality of NGS HLA typing data from the 34 participating IHIW laboratories. Completion of the PT program with a minimum score of 95% concordance at the HLA-A, HLA-B, HLA-C, HLA-DRB1 and HLA-DQB1 loci satisfied the requirements to submit NGS HLA typing data for the 17th IHIW projects. Together, these PS and PT efforts constituted the 17th IHIW Quality Control project. Overall PT concordance rates for HLA-A, HLA-B, HLA-C, HLA-DPA1, HLA-DPB1, HLA-DQA1, HLA-DQB1, HLA-DRB1, HLA-DRB3, HLA-DRB4 and HLA-DRB5 were 98.1%, 97.0% and 98.1%, 99.0%, 98.6%, 98.8%, 97.6%, 96.0%, 99.1%, 90.0% and 91.7%, respectively. Across all loci, the majority of the discordance was due to allele dropout. The high cost of NGS HLA genotyping per experiment likely prevented the retyping of initially failed HLA loci. Despite the high HLA genotype concordance rates of the software, there remains room for improvement in the assembly of more accurate consensus DNA sequences by NGS HLA genotyping software.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据