4.5 Article

Development of a lateral flow recombinase polymerase amplification assay for rapid and visual detection of Cryptococcus neoformans/C-gattii in cerebral spinal fluid

期刊

BMC INFECTIOUS DISEASES
卷 19, 期 -, 页码 -

出版社

BMC
DOI: 10.1186/s12879-019-3744-6

关键词

Cryptococcus neoformans; Cryptococcus gattii; Recombinase polymerase amplification; Lateral flow strips; Cerebral spinal fluid; Visual detection

资金

  1. National Natural Science Foundation of China [81702087]
  2. Shenzhen Scientific and Technological Foundation [JCYJ20160427152933037, JCYJ20160427152241973]
  3. Shenzhen Healthcare Research Project [201605010]

向作者/读者索取更多资源

BackgroundFor definitive diagnosis of cryptococcal meningitis, Cryptococcus neoformans and/or C. gattii must be identified within cerebral spinal fluid from the patients. The traditional methods for detecting Cryptococcus spp. such as India ink staining and culture are not ideal. Although sensitive and specific enough, detection of cryptococcal antigen polysaccharide has a high dose hook effect. Therefore, the aim of this study was to introduce a new rapid and simple detection method of Cryptococcus neoformans and C. gattii in cerebral spinal fluid.MethodsThe lateral flow strips combined with recombinase polymerase amplification (LF-RPA) assay was constructed to detect the specific DNA sequences of C. neoformans and C. gattii. The detection limit was evaluated using serial dilutions of C. neoformans and C. gattii genomic DNA. The specificity was assessed by excessive amount of other pathogens genomic DNA. The optimal detection time and amplification temperature were also analyzed. The diagnostic parameters were first calculated using 114 clinical specimens and then compared with that of other diagnostic method. A brief analysis and comparison of different DNA extraction methods was discussed, too.ResultsThe LF-RPA assay could detect 0.64pg of genomic DNA of C. neoformans per reaction within 10min and was highly specific for Cryptococcus spp.. The system could work well at a wide range of temperature from 25 to 45 degrees C. The overall sensitivity and specificity were 95.2 and 95.8% respectively. As amplification template for LF-RPA assay, both cell lysates and genomic DNA produce similar experimental results.ConclusionsThe LF-RPA system described here is shown to be a sensitive and specific method for the visible, rapid, and accurate detection of Cryptococcus spp. in cerebral spinal fluid and might be useful for clinical preliminary screening of cryptococcal meningitis.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据