4.7 Article

Magnetic Resonance Elastography for the Evaluation of Liver Fibrosis in Chronic Hepatitis B and C by Using Both Gradient-Recalled Echo and Spin-Echo Echo Planar Imaging: A Prospective Study

期刊

AMERICAN JOURNAL OF GASTROENTEROLOGY
卷 111, 期 6, 页码 823-833

出版社

NATURE PUBLISHING GROUP
DOI: 10.1038/ajg.2016.56

关键词

-

资金

  1. National Natural Science Foundation of China [81271566, 81471718, 81401376]
  2. National Institutes of Health grant [EB001981]

向作者/读者索取更多资源

OBJECTIVES: Magnetic resonance elastography (MRE) with three-dimensional spin-echo echo planar imaging (3D-SE-EPI) is a newly emerging noninvasive method for assessing liver fibrosis. We hypothesized that 3D-SE-EPI might have better diagnostic accuracy than conventional two-dimensional gradient-recalled echo (2D-GRE). METHODS: We prospectively included 179 consecutive patients with chronic hepatitis B (CHB) or C (CHC) who underwent both MRE and liver biopsy. Liver stiffness was measured by both 3D-SE-EPI and 2D-GRE for staging biopsy-proven liver fibrosis (using METAVIR scores). A receiver-operating characteristic analysis using the area under the receiver-operating characteristic curve (AUC) was used to compare the diagnostic performance in predicting liver fibrosis between these two techniques, and compared them to serum markers of fibrosis. RESULTS: The technical failure rate of 3D-SE-EPI (2.2%, n = 4/179) was lower compared with 2D-GRE (8.3%, n = 15/179). The stiffness measured by 3D-SE-EPI was slightly lower compared with 2D-GRE, with the mean difference of 0.57 kPa (Bland and Altman plot, 95% limits of agreement: -0.32 and 1.45 kPa). AUCs for the characterization of >= F1, >= F2, >= F3, and F4 were 0.957 (95% confidence interval (CI): 0.913-0.983), 0.971 (0.932-0.991), 0.991 (0.961-0.999), and 0.979 (0.942-0.995) for 3D-SE-EPI, which was slightly higher compared with the AUCs for 2D-GRE at each fibrosis stage (0.948 (0.901-0.977), 0.959 (0.915-0.981), 0.979 (0.943-0.995), and 0.976 (0.938-0.994), respectively), although none reached statistical significance (P = 0.160-0.585). In an intention-to-diagnose analysis, the diagnostic accuracy (the proportion of well-classified patients) by EPI (86.7-91.3%, n = 169) was higher compared with GRE (80.9-82.1%, n = 158) after applying optimal cutoffs. Both 3D-SE-EPI and 2D-GRE performed better than serum fibrosis markers. CONCLUSIONS: With respect to 2D-GRE, 3D-SE-EPI has the advantage of lower failure rate with equivalent high diagnostic performance for staging liver fibrosis in CHB/CHC patients, and thus more helpful for those challenging cases in 2D-GRE.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据