4.3 Article

Development of a Remote-Controlled Implantable Rat Sacral Nerve Stimulation System

期刊

NEUROMODULATION
卷 22, 期 6, 页码 690-695

出版社

WILEY
DOI: 10.1111/ner.12870

关键词

chronic; implantable stimulator; micturition; rats; sacral nerve stimulation

资金

  1. ANR, Programme Jeunes chercheurs-Jeunes Chercheuses Funding Source: Medline
  2. French ministry of research Funding Source: Medline
  3. French ministerial Funding Source: Medline
  4. Université de Rouen Funding Source: Medline
  5. Groupe d'Etude de Neuro-Urologie de Langue Française Funding Source: Medline

向作者/读者索取更多资源

Objectives Sacral nerve stimulation (SNS) is a surgical treatment of urinary and fecal incontinence. Despite its clinical efficacy, the mechanisms of action of SNS are still poorly known. This may be related to the use of acute stimulation models. Up to date, no rodent model of chronic SNS implants has been developed. Therefore, the aim of this study was to create a fully implantable and remotely controllable stimulating device to establish an animal model of chronic SNS. Materials and Methods The stimulating device consisted of an implantable pulse generator linked to a platinum electrode. The communication with the device was made through an inductive link which allowed to adjust the stimulation parameters; that is, to turn the device on and off or check the battery status remotely. Rats underwent two surgical procedures. In the first procedure, we achieved chronic sacral stimulation but the implanted electrode was not fixated. In the second procedure, the electrode was fixated in the sacral foramen using dental resin. In both cases, the correct positioning of the electrode was evaluated by computed tomography (CT) imaging and the presence of tail tremor in response to high intensity stimulation. We only tested the function of implanted electrode with fixation using micturition frequency assessment following bipolar or unipolar SNS for three days after recovery. Results CT imaging showed that implantation of the electrode required fixation as we found that the second surgical procedure yielded a more precise placement of the implanted electrode. The correct placement of implanted electrode observed with imaging was always correlated with a successful tail tremor response in rats, therefore we pursued our next experiments with the second surgical procedure and only assessed the tail tremor response. We found that both bipolar and unipolar SNS reduced micturition frequency. Conclusion This stimulating device provides an efficient method to perform chronic SNS studies in rats.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据