4.3 Article

An experimental study on the fault diagnosis of wind turbines through a condition monitoring system

期刊

JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY
卷 32, 期 12, 页码 5573-5582

出版社

KOREAN SOC MECHANICAL ENGINEERS
DOI: 10.1007/s12206-018-1103-y

关键词

Wind turbine; Operation &; maintenance; Condition monitoring system; Vibration analysis; Fault diagnosis

资金

  1. Korea Institute of Energy Technology Evaluation and Planning (KETEP)
  2. Ministry of Trade, Industry & Energy (MOTIE) of Republic of Korea [20163010024560, 20164030201230]
  3. Korea Evaluation Institute of Industrial Technology (KEIT) [20163010024560] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

To detect wind turbine faults at an early stage, an investigation into a practical maintenance and repair approach was carried out on Jeju Island, South Korea. A condition monitoring system was installed in each wind turbine nacelle to detect the vibration signals from the gearbox and the generator. The vibration signals were measured by strain gauges on the gearbox and the generator for a period of approximately one to two years. A time domain analysis to detect the components' faults was performed, and a frequency domain analysis was conducted to find the location of the faults that occurred. Using the criteria of acceptance level for the root mean square suggested in Verein Deutscher Ingenieure standard 3834, it was determined whether or not the gearbox and the generator were operated normally. After a fault was detected by root mean square analysis, the fast fourier transform spectrum was analyzed and then compared with that suggested by the International Organization for Standardization standard 10816-21 and 13373-1. Repair work was then conducted on the defective parts of the components. The root mean square and the acceleration value of the normal, the warning and the abnormal conditions were compared with one another. As a result, cavitation might occur in the gear oil pump attached to the gearbox due to the high acceleration values observed for frequencies ranging from 5000 Hz to 11000 Hz. Additionally, the generator bearing at the non drive end was found to be broken because the defect frequency of the bearing was 88 Hz, which was derived from envelope spectrum analysis. The root mean square and the acceleration values for the gearbox and the generator decreased to values indicating normal operating conditions after the damage repair. The annual energy production increased by 1.8 % after the generator bearing repair.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据