4.6 Article

The Delivery of High-Dose Dry Powder Antibiotics by a Low-Cost Generic Inhaler

期刊

AAPS JOURNAL
卷 19, 期 1, 页码 191-202

出版社

SPRINGER
DOI: 10.1208/s12248-016-9988-9

关键词

aerosolisation; dry powder inhaler; high-dose delivery; lung infection; modified Aerolizer (R)

资金

  1. Malaysian Government Scholarship
  2. University of Sydney
  3. Australian Research Council [DP150103953]
  4. National Health and Medical Research Council Centre of Research Excellence in Tuberculosis Control [APP1043225, APP104434]
  5. NSW Government Infrastructure Grant

向作者/读者索取更多资源

The routine of loading multiple capsules for delivery of high-dose antibiotics is time consuming, which may reduce patient adherence to inhaled treatment. To overcome this limitation, an investigation was carried out using four modified versions of the AerolizerA (R) that accommodate a size 0 capsule for delivery of high payload formulations. In some prototypes, four piercing pins of 0.6 mm each were replaced with a single centrally located 1.2-mm pin and one-third reduced air inlet of the original design. The performance of these inhalers was evaluated using spray-dried antibiotic powders with distinct morphologies: spherical particles with a highly corrugated surface (colistin and tobramycin) and needle-like particles (rifapentine). The inhalers were tested at capsule loadings of 50 mg (colistin), 30 mg (rifapentine) and 100 mg (tobramycin) using a multistage liquid impinger (MSLI) operating at 60 L/min. The device with a single pin and reduced air inlet showed a superior performance than the other prototypes in dispersing colistin and rifapentine powders, with a fine particle fraction (FPF wt% < 5 mu m in the aerosol) between 62 and 68%. Subsequently, an AerolizerA (R) with the same configuration (single pin and one-third air inlet) that accommodates a size 00 capsule was designed to increase the payload of colistin and rifapentine. The performance of the device at various inspiratory flow rates and air volumes achievable by most cystic fibrosis (CF) patients was examined at the maximum capsule loading of 100 mg. The device showed optimal performance at 45 L/min with an air volume of 1.5-2.0 L for colistin and 60 L/min with an air volume of 2.0 L for rifapentine. In conclusion, the modified size 00 AerolizerA (R) inhaler as a low-cost generic device demonstrated promising results for delivery of various high-dose formulations for treatment of lung infections.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据