4.7 Article

Heat transfer and fouling performance of finned tube heat exchangers: Experimentation via on line monitoring

期刊

FUEL
卷 236, 期 -, 页码 949-959

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.fuel.2018.09.081

关键词

Waste heat recovery; On line experiment; H-type finned tube; Heat transfer; Fouling

资金

  1. National Key R&D Program of China [2016YFB0601100]
  2. Foundation for Innovative Research Groups of the National Natural Science Foundation of China [51721004]
  3. 111 Project [B16038]
  4. China Scholarship Council

向作者/读者索取更多资源

An on line experimental system was set up in a heating boiler so as to reproduce dusty working environments in heat recovery systems and to investigate heat transfer and fouling performance of different kinds of finned tube heat exchangers. Measurements are reported for the heat transfer coefficients, fouling and the effect of fouling on heat transfer performance of five different H-type finned tube heat exchangers. Fouling resistance and the weakened degree of heat transfer coefficient are employed to evaluate the effect of fouling on the heat transfer performance. Numerical simulations are also conducted on the fouling performance of each heat exchanger bundle and compared to the measurements. Double H-type fins can slightly reduce the heat transfer performance but also reduce fouling. Elliptical finned tubes with the same tube pitch decrease heat transfer performance and increase fouling, and with the same relative tube pitch, significantly increase the heat transfer performance before fouling, and can effectively reduce fouling.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据