期刊
CRYOGENICS
卷 98, 期 -, 页码 107-112出版社
ELSEVIER SCI LTD
DOI: 10.1016/j.cryogenics.2018.12.010
关键词
Integral type; Stepped warm displacer; Stepped displacer diameter; Expansion space volume
资金
- National Natural Science Foundation of China [51576205]
- Youth Innovation Promotion Association CAS [2017040]
- CAS International Cooperation Program [1A1111KYSB20160087]
This paper presented an integral hybrid two-stage pulse tube cooler, which works at liquid hydrogen temperature and uses stepped warm displacers as the phase shifter. The integral configuration with dual-opposed displacers and dual-opposed compressor pistons was adopted to improve the cooling performance and compactness of the system. Influences of key parameters of the stepped warm displacer on cooling performance were numerically analyzed. Based on the simulations, experiments were carried out. A cooling power of 1.2 W at 20 K was obtained with an input electric power of 303 W and the corresponding relative Carnot efficiency reached 5.42%. The influences of some operating parameters were also experimentally investigated.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐