3.9 Article

Measurable Outcomes of Quality Improvement Using a Daily Quality Rounds Checklist: One-Year Analysis in a Trauma Intensive Care Unit With Sustained Ventilator-Associated Pneumonia Reduction

期刊

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/TA.0b013e3181c4526f

关键词

Trauma; Intensive care; Quality improvement; Ventilator-associated pneumonia; Prophylaxis

向作者/读者索取更多资源

Background: We have previously demonstrated that the use of a daily Quality Rounds Checklist (QRC) can increase compliance with evidence-based prophylactic measures and decrease complications in a busy trauma intensive care unit (ICU) over a 3-month period. This study was designed to determine the sustainability of QRC use over 1 year and examine the relationship between compliance and outcome improvement. Methods: A prospective before-after design was used to examine the effectiveness of the QRC tool in documenting compliance with 16 prophylactic measures for ventilator-associated pneumonia (VAP), deep venous thrombosis, pulmonary embolism, catheter-related bloodstream infection, and other ICU complications. The QRC was implemented on a daily basis for a 1-year period by the ICU fellow on duty. Monthly compliance rates were assessed by a multidisciplinary team for development of strategies for real-time improvement. Compliance and outcomes were captured over 1 year of QRC use. Results: QRC use was associated with a sustained improvement of VAP bundle and other compliance measures over a year of use. After multivariable analysis adjusting for age (>55), injury mechanism, Glasgow Coma Scale score(<= 8), and Injury Severity Score (>20), the rate of VAP was significantly lower after QRC use, with an adjusted mean difference of -6.65 (per 1,000 device days; 95% confidence interval, -9.27 to -4.04; p = 0.008). During the year of QRC use, 3% of patients developed a VAP if all four daily bundle measures were met for the duration of ICU stay versus 14% in those with partial compliance (p = 0.04). The overall VAP rate with full compliance was 5.29 versus 9.23 (per 1,000 device days) with partial compliance. Compared with the previous year, a 24% decrease in the number of pneumonias was recorded for the year of QRC use, representing an estimated cost savings of approximately $400,000. Conclusion: The use of a QRC facilitates sustainable improvement in compliance rates for clinically significant prophylactic measures in a busy Level I trauma ICU. The daily use of the QRC, requiring just a few minutes per patient to complete, equates to cost-effective improvement in patient outcomes.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.9
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据