4.6 Article

A new procedure combining GC-MS with accelerated solvent extraction for the analysis of phthalic acid esters in contaminated soils

期刊

出版社

HIGHER EDUCATION PRESS
DOI: 10.1007/s11783-012-0463-2

关键词

phthalic acid esters; quality assurance and quality control; soil type; accelerated solvent extraction; certified reference materials

资金

  1. China National Environmental Protection Special Funds for Scientific Research on Public Causes Studies on the regulation of agricultural soil environmental quality, environmental risk and key control techniques [201109018]
  2. Program of Innovative Engineering of the Chinese Academy of Sciences [KZCX2-YW-Q02-06-02]

向作者/读者索取更多资源

An optimized procedure based on gas chromatography-mass spectrometry (GC-MS) combined with accelerated solvent extraction (ASE) is developed for the analysis of six phthalic acid esters (PAEs), which are priority soil pollutants nominated by United States Environmental Protection Agency (USEPA). Quantification of PAEs in soil employs ultrasonic extraction (UE) (USEPA 3550) and ASE (USEPA 3545), followed by clean up procedures involving three different chromatography columns and two combined elution methods. GC-MS conditions under selected ion monitoring (SIM) mode are described and quality assurance and quality control (QA/QC) criteria with high accuracy and sensitivity for target analytes were achieved. Method reliability is assured with the use of an isotopically labeled PAE, di-n-butyl phthalate-d4 (DnBP-D4), as a surrogate, and benzyl benzoate (BB) as an internal standard, and with the analysis of certified reference materials (CRM). QA/QC for the developed procedure was tested in four PAE-spiked soils and one PAE-contaminated soil. The four spiked soils were originated from typical Chinese agricultural fields and the contaminated soil was obtained from an electronic waste dismantling area. Instrument detection limits (IDLs) for the six PAEs ranged 0.10-0.31 mu g.L-1 and method detection limits (MDLs) of the four spiked soils varied from a range of 20-70 mu g.kg(-1) to a range of 90-290 mu g.kg(-1). Linearity of response between 20 mu g.L-1 and 2 mg.L-1 was also established and the correlation coefficients (R) were all > 0.998. Spiked soil matrix showed relative recovery rates between 75 and 120% for the six target compounds and about 93% for the surrogate substance. The developed procedure is anticipated to be highly applicable for field surveys of soil PAE pollution in China.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据