4.6 Article

Value of Cardiovascular Magnetic Resonance Stress Perfusion Testing for the Detection of Coronary Artery Disease in Women

期刊

JACC-CARDIOVASCULAR IMAGING
卷 1, 期 4, 页码 436-445

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jcmg.2008.03.010

关键词

CAD; women; stress CMR

资金

  1. Kliniken Miltenberg-Erlenbach GmbH [R01-HL64726, R01-HL63268]

向作者/读者索取更多资源

OBJECTIVES We wanted to assess the value of cardiovascular magnetic resonance (CMR) stress testing for evaluation of women with suspected coronary artery disease (CAD). BACKGROUND A combined perfusion and infarction CMR examination can accurately diagnose CAD in the clinical setting in a mixed gender population. METHODS We prospectively enrolled 147 consecutive women with chest pain or other symptoms suggestive of CAD at 2 centers (Duke University Medical Center, Robert-Bosch-Krankenhaus). Each patient underwent a comprehensive clinical evaluation, a CMR stress test consisting of cine rest function, adenosine-stress and rest perfusion, and delayed-enhancement CMR infarction imaging, and X-ray coronary angiography within 24 h. The components of the CMR test were analyzed visually both in isolation and combined using a pre-specified algorithm. Coronary artery disease was defined as stenosis similar to 70% on quantitative analysis of coronary angiography. RESULTS Cardiovascular magnetic resonance imaging was completed in 136 females (63.0 +/- 11.1 years), 37 (27%) women had CAD on coronary angiography. The combined CMR stress test had a sensitivity, specificity, and accuracy of 84%, 88%, and 87%, respectively, for the diagnosis of CAD. Diagnostic accuracy was high at both sites (Duke University Medical Center 82%, Robert-Bosch-Krankenhaus 90%; p = 0.18). The accuracy for the detection of CAD was reduced when intermediate grade stenoses were included (82% vs. 87%; p = 0.01 compared the cutoff of stenosis >= 50% vs. >= 70%). The sensitivity was lower in women with single-vessel disease (71% vs. 100%; p = 0.06 compared with multivessel disease) and small left ventricular mass (69% vs. 95%; p = 0.04 for left ventricular mass <= 97 g vs. >97 g). The latter difference was even more significant after accounting for end-diastolic volumes (70% vs. 100%; p = 0.02 for left ventricular mass indexed to end-diastolic volume <= 1.15 g/ml vs. >1.15 g/ml). CONCLUSIONS A multicomponent CMR stress test can accurately diagnose CAD in women. Detection of CAD in women with intermediate grade stenosis, single-vessel disease, and with small hearts is challenging. (J Am Coll Cardiol Img 2008; 1: 436-45) (C) 2008 by the American College of Cardiology Foundation

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据