4.5 Article

Performance of a constructed wetland for treating farm-yard dirty water

期刊

WATER SCIENCE AND TECHNOLOGY
卷 64, 期 1, 页码 22-28

出版社

IWA PUBLISHING
DOI: 10.2166/wst.2011.584

关键词

BOD; constructed wetland; nutrients; pathogens; reductions

向作者/读者索取更多资源

Constructed wetlands (CWs) have been used to treat agricultural effluents with varying success especially with respect to their operational efficiency in winter and ability to retain phosphorus. Dirty water (DW) from dairy farms is a mixture of manure contaminated runoff and milk parlour washings with a highly polluting biochemical oxygen demand (BOD) <= 3,000 mg/L. The initial performance a CW of a 1.2 ha horizontal flow CW consisting of five ponds in series designed to treat DW from a dairy unit was assessed over four years. Ponds were earth-lined and shallow (0.3 m) with a water residence time of 100 days and planted with five species of emergent macrophytes. In comparison to CW inflow, annual reductions were as follows: BOD 99%, P 95% and N 92.8%. Coliforms were reduced by a 10(-5) factor to natural levels. From May to October there was little CW discharge due to evaporative losses. Final effluent quality was poorest in February but remained within a regulatory effluent standard for BOD of 40 mg/ L. If the CW had only four ponds (25% less surface area) effluent would have failed the BOD standard in three years.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据