期刊
WATER AIR AND SOIL POLLUTION
卷 221, 期 1-4, 页码 183-189出版社
SPRINGER
DOI: 10.1007/s11270-011-0781-1
关键词
Zero-valent iron; Zinc; Adsorption; Co-precipitation; Corrosion; Dissolved oxygen
Mechanism of zinc iron removal by zero-valent iron was discussed through zinc removal responses to several operational conditions of a packed column reactor with zero-valent iron powder. The adsorption isotherm observed implied that a kind of chemisorption was responsible for zinc removal. Zinc removal by zero-valent iron was enhanced by dissolved oxygen and ferric ion addition. However, it was deteriorated under acidic pH. In addition, zinc adsorbed on zero-valent iron was eluted by a reducing agent such as citric acid, whereas the zinc was not eluted by diluted sulfuric acid. Consequently, the zinc removal mechanism by zero-valent iron was inferred to be as follows: Zero-valent iron was firstly corroded and oxidized into ferric ion by dissolved oxygen. The ferric ion was precipitated as iron hydroxide onto the surface of the zero-valent iron powder. Zinc ion was adsorbed on and/or coprecipitated with the iron hydroxide. The iron hydroxide was finally oxidized and transformed into iron oxides.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐