期刊
WASTE MANAGEMENT
卷 30, 期 7, 页码 1355-1361出版社
PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.wasman.2009.09.008
关键词
-
Gas cleaning systems of MSW (Municipal Solid Waste) incinerators are characterised by the process employed to remove acid gases. The commonly used technologies for acid gas removal are: (1) dry treatment with Ca(OH)(2) or (2) with NaHCO3, (3) semi-dry process with Ca(OH)(2) and (4) wet scrubbing. In some recent plants beside a wet cleaning system, a dry neutralization with Ca(OH)(2) is used. The goal is to reduce the amount of acid to be removed in the wet treatment and the liquid effluents produced. The influence of these different technologies on the electrical efficiency was investigated by a detailed simulation of a WTE (Waste To Energy) plant with a capacity of about 100,000 t/y of MSW. The effects of the different gas cleaning systems on electrical efficiency were significant. The difference of efficiency between the most advantageous technology, which is dry treatment with NaHCO3, and the least advantageous technology which is semi-dry treatment, is about 0.8%. A simple economic analysis showed that the few advantages of dry technologies can often be lost if the costs of chemicals and the disposal of products are considered. (C) 2009 Elsevier Ltd. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据