4.4 Article

Restoration of weak phase-contrast images recorded with a high degree of defocus: The twin image problem associated with CTF correction

期刊

ULTRAMICROSCOPY
卷 108, 期 9, 页码 921-928

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.ultramic.2008.03.004

关键词

CTF correction; delocalization; twin image; phase-contrast EM

资金

  1. U.S. Department of Energy [DE-AC02-05CH11231]
  2. NIH [GM51487, GM083039]

向作者/读者索取更多资源

Relatively large values of objective-lens defocus must normally be used to produce detectable levels of image contrast for unstained biological specimens, which are generally weak phase objects. As a result, a subsequent restoration operation must be used to correct for oscillations in the contrast transfer function (CTF) at higher resolution. Currently used methods of CTF correction assume the ideal case in which Friedel mates in the scattered wave have contributed pairs of Fourier components that overlap with one another in the image plane. This ideal situation may be only poorly satisfied, or not satisfied at all, as the particle size gets smaller, the defocus value gets larger, and the resolution gets higher. We have therefore investigated whether currently used methods of CTF correction are also effective in restoring the single-sideband image information that becomes displaced (delocalized) by half (or more) the diameter of a particle of finite size. Computer simulations are used to show that restoration either by phase flipping or by multiplying by the CTF recovers only about half of the delocalized information. The other half of the delocalized information goes into a doubly defocused twin image of the type produced during optical reconstruction of an in-line hologram. Restoration with a Wiener filter is effective in recovering the delocalized information only when the signal-to-noise ratio (S/N) is orders of magnitude higher than that which exists in low-dose images of biological specimens, in which case the Wiener filter approaches division by the CTF (i.e. the formal inverse). For realistic values of the S/N, however, the twin image problem seen with a Wiener filter is very similar to that seen when either phase flipping or multiplying by the CTF is used for restoration. The results of these simulations suggest that CTF correction is a poor alternative to using a Zernike-type phase plate when imaging biological specimens, in which case the images can be recorded in a close-to-focus condition, and delocalization of high-resolution information is thus minimized. (c) 2008 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据