期刊
TOXICOLOGIC PATHOLOGY
卷 40, 期 1, 页码 113-121出版社
SAGE PUBLICATIONS INC
DOI: 10.1177/0192623311425063
关键词
sarcomatosis; peritoneum; telemetry implants; CD rats
Surgical implantation of radiotelemetric transmitters is a current practice to collect a variety of physiological parameters in unrestrained laboratory animals, and in rodents in particular. In this study, the incidence of peritoneal sarcomatosis arising secondary to surgically implanted telemetry devices (< 15% of implanted Sprague Dawley rats) is considered to represent a significant issue for both animal welfare and data validity in affected animals. Macroscopically, the telemetry-associated fibrosarcomas spread along the visceral and parietal peritoneum and mesentery surrounding abdominal organs. The histologic morphology of these sarcomas was typically an undifferentiated sarcoma, although well-differentiated fibrosarcomas and telangiectatic and pleomorphic variants were noted. Using special stains such as Masson's Trichrome demonstrated a collagenous extracellular matrix in 50% of these rats, which is consistent with a fibroblastic origin. Immunohistochemical studies clearly delineated the mesenchymal components of the sarcomas (fibroblasts and smooth muscle cells); one case, however, was diagnosed as an osteosarcoma.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。