4.7 Article

A rapid and easy method based on hydrophilic interaction chromatography coupled with tandem mass spectrometry (HILIC-MS/MS/MS) to quantify iodinated X-ray contrast in wastewaters

期刊

TALANTA
卷 190, 期 -, 页码 480-486

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.talanta.2018.08.006

关键词

HILIC; MRM3; Contrast agent; Sewage; Quantification

向作者/读者索取更多资源

This work proposes the first method based on hydrophilic interaction liquid chromatography coupled to multiple reaction monitoring with triple stage fragmentation (HILIC-MRM3) to quantify polar organic micropollutants in complex sewage waters. A fast HILIC-MRM3 analytical method, without sample preparation except a dilution step, was developed and validated to quantify seven iodinated contrast media (ICMs) in sewage waters, namely iohexol, iomeprol, ioversol, iopamidol, diatrizoic acid, iopromide and iopentol. Several chromatographic columns and mobile phase conditions were investigated and a good separation of the ICMs was obtained with a mixed-mode column (Acclaim Mixed-mode WAX) used in HILIC conditions. The validation was performed using a synthetic matrix: the limits of quantification (LOQ) were inferior to 1 g/L and the linearity of each compound was comprised within the [0.5-50] g/L range. The applicability of the HILIC-MRM3 method was assessed by the analysis of several raw waters. The results highlighted the presence of ICMs in most samples, at concentrations up to several mg/L in hospital sewage waters.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据