Design and evaluation of a portable optical-based biosensor for testing whole blood prothrombin time

期刊

TALANTA
卷 116, 期 -, 页码 704-711

出版社

ELSEVIER
DOI: 10.1016/j.talanta.2013.07.064

关键词

Point-of-care diagnostics; Prothrombin time; Optical-based device; Whole blood; Biosensor; Light transmittance

资金

  1. National Science Council of Taiwan [NSC99-2622-B-006-002-CC1, NSC100-2622-B-006-005-CC1]

向作者/读者索取更多资源

Point-of-care diagnostics (POCD) for blood coagulation benefit patients on-site, but available POCD devices are too expensive to be affordable in many countries. Optically based methodologies are cheap and reliable, and have been exploited in bench-top coagulometers to monitor coagulation with plasma, but not whole blood, which contains cellular components that cause massive interference. However, the POCD testing of whole blood gives a more accurate picture of physiological conditions than does testing plasma. In this study, a portable device for performing the prothrombin time (PT) test was designed, comprising an optical sensor, an electrical processing and control circuit to monitor the optical changes that occurred during the coagulation process in whole blood. The PT was when the slope of the first-order derivative of the coagulation curve, recorded from real-time light transmittance signals, was maximal. The POCD PT testing of 167 samples revealed that 153 (91.6%) were successfully detected and the results were highly consistent with the results of whole blood international normalized ratio (INR) (r=0.985, p < 0.001) by the conventional manual method and those of plasma INR (r=0.948, p < 0.001) with the ACL TOP 700 bench-top coagulometer (Beckman Colter). Hematological parameters were further analyzed, revealing that fibrinogen titers (p=0.036), red blood cell numbers (p=0.017) and distribution of red cell width (p=0.015) affected the effectiveness of the current POCD PT determination. Furthermore, a highly positive correlation was revealed between fibrinogen titers and the maximum speed of change in transmittance (v/t) (r=0.805, p < 0.001), suggesting that fibrinogen might be evaluated simultaneously in this POCD testing. In conclusion, the proposed portable optical-based device performs the highly sensitive and accurate determination of whole blood PT and has commercial potential because of its small volume and low fabrication cost. (C) 2013 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据