4.3 Article

Sperm with large nuclear vacuoles and semen quality in the evaluation of male infertility

期刊

SYSTEMS BIOLOGY IN REPRODUCTIVE MEDICINE
卷 59, 期 1, 页码 13-20

出版社

TAYLOR & FRANCIS INC
DOI: 10.3109/19396368.2012.729174

关键词

DIC; male infertility; semen analysis; Sperm Motility Analysis System; sperm nuclear vacuole

向作者/读者索取更多资源

This study compared the sperm nuclear vacuoles and semen quality in the evaluation of male infertility. One hundred and forty-two semen samples were obtained from patients who visited the Male Infertility Clinic at Toyama University Hospital. Semen samples were evaluated by conventional semen analyses and the Sperm Motility Analysis System (SMAS). In addition, spermatozoa were analyzed at 3,700-6,150x magnification on an inverted microscope equipped with DIC/Nomarski differential interference contrast optics. A large nuclear vacuole (LNV) was defined as one or more vacuoles with the maximum diameter showing > 50% width of the sperm head. The percentage of spermatozoa with LNV (% LNV) was calculated for each sample. Correlations between the % LNV and parameters in SMAS and conventional semen analyses were analyzed. Processed motile spermatozoa from each sample were evaluated. The mean age of patients was 35 years old. Semen volume was 2.9 +/- 1.6mL (0.1-11.0; mean +/- standard deviation, minimum-maximum), sperm count was 39.3 +/- 54.9 (x10(6)/mL, 0.01-262.0), sperm motility was 25.1 +/- 17.8% (0-76.0), and normal sperm morphology was 10.3 +/- 10.1% (0-49.0). After motile spermatozoa selection, we could evaluate % LNV in 125 ejaculates (88.0%) and at least one spermatozoon with LNV was observed in 118 ejaculates (94.4%). The percentage of spermatozoa with LNV was 28.0 +/- 22.4% (0-100) and % LNV increased significantly when semen quality decreased. The correlation between the % LNV and the semen parameters was weak to moderate; correlation coefficients were -0.3577 in sperm count (p < 0.0001), -0.2368 in sperm motility (p = 0.0084), -0.2769 in motile sperm count (p = 0.019), -0.2419 in total motile sperm count (p = 0.0070), and -0.1676 in normal sperm morphology (p = 0.0639). The % LNV did not show a significant correlation with the SMAS parameters except for weak correlation to beat/cross frequency (r = -0.2414, p = 0.0071). The percentage of spermatozoa with LNV did not have a strong correlation with parameters in conventional semen analysis and SMAS in the patients with male infertility; however, a certain level of negative influence of LNV to sperm quality cannot be excluded.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据