期刊
SPINE
卷 37, 期 24, 页码 2055-2060出版社
LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/BRS.0b013e31825c05cd
关键词
computer-aided surgery; fluoroscopy; navigation guidance; minimally invasive; radiation
资金
- NuVasive funds
Study Design. Institutional review board-approved, prospective, multicenter, comparative study. Objective. To assess the accuracy and utility of a computer-assisted fluoroscopic navigation method for percutaneous placement of lumbar pedicle screws compared with conventional fluoroscopic placement. Summary of Background Data. Recent reports indicate that cortical breaches during percutaneous pedicle screw placement can exceed 15%. Computed tomography (CT)-and fluoroscopy-based navigation systems may facilitate increased placement accuracy with reduced radiation exposure and operative times. Methods. Patients were alternately assigned to either the Guidance or Control group. The Guidance group underwent lumbar pedicle screw placement using the oblique visualization technique and computer-assisted fluoroscopic navigation. The Control group underwent lumbar pedicle screw placement per standard percutaneous technique aided by fluoroscopy alone. Baseline demographics, visual analog scale (VAS) pain scores, and American Spinal Injury Association scores were obtained preoperatively and in the immediate postoperative period. Fluoroscopy times and guidewire insertion times were recorded intraoperatively. All postoperative CT scans were reviewed by an independent spine surgeon to grade screw placement accuracy. Results. Forty-two patients (210 screws) were assigned to the Guidance group and 34 patients (152 screws) were assigned to the Control group. Use of Guidance resulted in reduced average fluoroscopy usage per pedicle [6.6 sec (SD = 5.1) vs. 9.6 sec (SD 6.2), P < 0.001] and more expedient placement of guidewires per pedicle [3.65 min (SD = 2.31) vs. 4.43 min (SD = 2.56), P = 0.003]. The Guidance group experienced less than half of the breach rate of the Control group (3.0% vs. 7.2%, P = 0.055) and reduced breach magnitudes. None of the breaches resulted in a corresponding neurological deficit or required revision. All patient-reported outcomes were significantly improved after surgery and there were no significant differences in average postoperative VAS scores between treatment groups. Conclusion. Use of Guidance reduces fluoroscopy and insertion times with increased accuracy compared with conventional fluoroscopic methods of percutaneous pedicle screw insertion.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据