期刊
SEPARATION AND PURIFICATION TECHNOLOGY
卷 136, 期 -, 页码 150-156出版社
ELSEVIER
DOI: 10.1016/j.seppur.2014.09.006
关键词
Continuous electrocoagulation; Groundwater; Arsenic removal; NOM removal; Residual aluminium
资金
- Ministry of Education, Science and Technological Development of the Republic of Serbia [11143005]
- Provincial Secretariat for Science and Technological Development of Vojvodina [APV114-451-1985]
A novel technique of continuous ECF using bipolar Al electrode was attempted in this study to efficiently remove arsenic from groundwater rich in hydrophobic NOM (9.31 +/- 0.52 mg C/L). The effects of several operational parameters such as, initial groundwater pH, evolution of temperature, conductivity and pH, electrode polarity time change on As and NOM removal efficiency were comprehensively examined by conducting 6 h long experimental runs. The average residual As in treated groundwater was 4.6 +/- 0.4 mu g/L. NOM removal according to UV254 absorbance, DOC and SUVA was 89%, 70%, 64%, respectively. The highest As and NOM removal with the optimal residual Al below 0.2 mg/L was obtained at the same groundwater pH = 5.3 +/- 0.3. The change of electrode polarity at 30 min successfully prevented electrode passivation and enabled highest As removal with the optimal residual Al in treated groundwater. Specific reactor electric energy and electrode consumption for operational current density of 8.86 mA/cm(2) was 3.03 kW h/m(3), 0.059 kg Al/m(3), respectively. Indicative reactor's operating cost at the optimal operational conditions was estimated at 0.25 (sic)/m(3). (C) 2014 Elsevier B.V. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐