4.7 Article

Development of a new fluorescent sensor based on a triazolo-thiadiazin derivative immobilized in polyvinyl chloride membrane for sensitive detection of lead(II) ions

期刊

SENSORS AND ACTUATORS B-CHEMICAL
卷 157, 期 1, 页码 162-168

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2011.03.044

关键词

Optical sensor; PVC matrix; Fluorescence spectroscopy; Fluorescence enhancement; Lead(II); Triazolo-thiadiazin

向作者/读者索取更多资源

A new sensor membrane based on a novel triazolo-thiadiazin derivative immobilized in polyvinyl chloride has been developed for the determination of Pb(II) ions that displays excellent performance. The parameters involved in the preparation of the optode and determination of Pb(II) were optimized. Under the optimal conditions, the proposed sensor displays a calibration response for Pb(II) over a wide concentration range of 5.0 X 10(-8) to 3.8 x 10(-4) M with the detection limit of 2.2 x 10(-8) M. In addition to high reproducibility and reversibility of the fluorescence signal, the sensor also exhibits good selectivity over common metal ions. The optode membrane developed is easily prepared, stable, rapid, and simple for the determination of Pb(II). The accuracy of the proposed sensor was confirmed by analyzing standard reference materials of natural water and surface water. The sensor was successfully used for the determination of Pb(II) ions in water samples with satisfactory results. (C) 2011 Elsevier B.V. All rights reserved.