期刊
SENSORS AND ACTUATORS B-CHEMICAL
卷 131, 期 1, 页码 318-322出版社
ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2007.11.029
关键词
SnO2; sensor response; CO; ac impedance
A SnO2 layer was prepared by an electrodeposition process, followed by an oxidation step. The SnO2 layer was porous, highly pure and of cubic crystalline structure. dc potential and ac impedance methods were used to detect the sensor response of the SnO2 layer to CO in air and in H2SO4 (aq). In air the sensor response increased with increasing temperature and revealed the largest values at 623 K and in H2SO4 (aq) the response started from room temperature and sensed a CO concentration as low as 100 ppm. The ac impedance method was promising to detect the sensor response of SnO2 to CO. (c) 2007 Elsevier B.V. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐