4.7 Article

Continuum electromechanics of a magnetorheological damper including the friction force effects between the MR fluid and device walls: Analytical modelling and experimental validation

期刊

SENSORS AND ACTUATORS A-PHYSICAL
卷 155, 期 1, 页码 82-88

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.sna.2009.08.004

关键词

Magnetorheologic damper; MR fluid; Electroactive fluids

向作者/读者索取更多资源

In this paper an analytical and experimental evaluation of a magnetorheological damper is described. Based on modelling the friction force effects between the MR fluid and the device walls, a continuum electromechanical model describing the damper behaviour is formulated. A magnetorheological device was fabricated to validate the model being tested under static and steady-state load conditions and applied magnetic field values. The friction coefficient and the magnetic permeability of the MR fluid are estimated experimentally, and the effectiveness of the proposed model is verified. (C) 2009 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据