4.4 Article

Tendon sheath analysis for estimation of distal end force and elongation for sensorless distal end

期刊

ROBOTICA
卷 28, 期 -, 页码 1073-1082

出版社

CAMBRIDGE UNIV PRESS
DOI: 10.1017/S026357470999083X

关键词

Surgical Robots; Grasping; Force Control; Serial Manipulator Design and Kinematics; Haptic Interfaces

类别

资金

  1. National Medical Research Council (Singapore) [NMRC/1082/2006, NMRC/TCR/001/2007]

向作者/读者索取更多资源

Tendon sheath actuation is found in many applications, particularly in robotic hands and surgical robots. Due to the friction between the tendon and sheath, many undesirable characteristic such as backlash, hysteresis and non-linearity are present. It is desirable to know the end-effector force and elongation of the tendon to control the system effectively, but it is not always feasible to fix sensors at the end effector. A method to estimate the end-effector parameters using only a force and position sensor at the proximal site is given. An analytical study is presented and experiments are reported to support the result, showing a maximum full-scale error of approximately 7%. This result is achieved if the shape of the sheath remains the same and buckling is negligible. The results presented in this study could contribute towards haptic development in robotics surgery.