4.7 Article

Carotid Artery Stenosis: Accuracy of Noninvasive Tests-Individual Patient Data Meta-Analysis

期刊

RADIOLOGY
卷 251, 期 2, 页码 493-502

出版社

RADIOLOGICAL SOC NORTH AMERICA
DOI: 10.1148/radiol.2512080284

关键词

-

资金

  1. United Kingdom National Health Service Research and Development Health Technology Assessment Programme [01/37/03]
  2. SFC Brain Imaging Research Centre for Scotland and Scottish Executive Health Department Chief Scientist Office [CZF/1/23]
  3. National Institute for Health Research [01/37/03] Funding Source: researchfish

向作者/读者索取更多资源

Purpose: To find clinically relevant estimates of the accuracy of noninvasive imaging-Doppler ultrasonography (US), computed tomographic (CT) angiography, magnetic resonance (MR) angiography, and contrast material-enhanced MR angiography -in diagnosing both severe and moderate symptomatic carotid artery stenosis; to ascertain the effect of prespecified clinical factors and clinical setting on diagnostic accuracy; and to estimate the probability of agreement between two noninvasive tests. Materials and Methods: Original principal investigators obtained ethics approval for each data set. All data were anonymized. Individual patient data sets (IPDs) for noninvasive imaging tests were used to determine sensitivity, specificity, and agreement between the tests for symptomatic carotid artery stenosis; to compare ipsilateral with contralateral arteries; to compare IPDs with literature estimates; to compare routine audit and research data; and to determine the effect of age and sex on sensitivity and specificity. Results: Contrast-enhanced MR angiography was the most accurate (sensitivity, 0.85 [30 of 35]; 95% confidence interval [CI]: 0.69, 0.93; and specificity, 0.85 [67 of 78]; 95% CI: 0.76, 0.92) for 70%-99% symptomatic stenosis. Sensitivity for a 50%-69% stenosis was poor, although data were limited. Sensitivity and specificity were generally lower in the ipsilateral than in the contralateral artery. IPD estimates were lower than literature values. Results of comparison of research with audit-derived data were inconclusive. Neither age nor sex affected accuracy. Agreement was better between two Doppler US tests and between two contrast-enhanced MR angiographic tests than it was between Doppler US and contrast-enhanced MR angiography, except for a 70%-99% symptomatic stenosis. Conclusion: Primary studies should distinguish ipsilateral from contralateral arteries and carefully describe the patients' characteristics and study environment. The literature overestimates noninvasive imaging accuracy. More data are needed to inform physicians in routine clinical practice.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据