期刊
PLOS ONE
卷 9, 期 3, 页码 -出版社
PUBLIC LIBRARY SCIENCE
DOI: 10.1371/journal.pone.0090300
关键词
-
资金
- Manchester Cancer Research Centre
- Cancer Research UK [16465, 18097] Funding Source: researchfish
Purpose: To compare semi-quantitative (SQ) and pharmacokinetic (PK) parameters for analysis of dynamic contrast enhanced MR data (DCE-MRI) and investigate error-propagation in SQ parameters. Methods: Clinical data was collected from five patients with type 2-neurofibromatosis (NF2) receiving anti-angiogenic therapy for rapidly growing vestibular schwannoma (VS). There were 7 VS and 5 meningiomas. Patients were scanned prior to therapy and at days 3 and 90 of treatment. Data was collected using a dual injection technique to permit direct comparison of SQ and PK parameters. Monte Carlo modeling was performed to assess potential measurement errors in SQ parameters in persistent, washout, and weakly enhancing tissues. The simulation predictions for five semi-quantitative parameters were tested using the clinical DCE-MRI data. Results: In VS, SQ parameters and K-trans showed close correlation and demonstrated similar therapy induced reductions. In meningioma, only the denoised Signal Enhancement Ratio (R-se1/se2(DN)) showed a significant therapy induced reduction (p<0.05). Simulation demonstrated: 1) Precision of SQ metrics normalized to the pre-contrast-baseline values (MSErel and Sigma MSErel) is improved by use of an averaged value from multiple baseline scans; 2) signal enhancement ratio R-mse1/mse2 shows considerable susceptibility to noise; 3) removal of outlier values to produce a new parameter, R-mse1/mse2(DN), improves precision and sensitivity to therapy induced changes. Direct comparison of in-vivo analysis with Monte Carlo simulation supported the simulation predicted error distributions of semi-quantitative metrics. Conclusion: PK and SQ parameters showed similar sensitivity to anti-angiogenic therapy induced changes in VS. Modeling studies confirmed the benefits of averaging baseline signal from multiple images for normalized SQ metrics and demonstrated poor noise tolerance in the widely used signal enhancement ratio, which is corrected by removal of outlier values.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据