4.6 Article

Evaluation of Inhibitor-Resistant Real-Time PCR Methods for Diagnostics in Clinical and Environmental Samples

期刊

PLOS ONE
卷 8, 期 9, 页码 -

出版社

PUBLIC LIBRARY SCIENCE
DOI: 10.1371/journal.pone.0073845

关键词

-

资金

  1. Defense Threat Reduction Agency [8.10041_08_RD_B]

向作者/读者索取更多资源

Polymerase chain reaction (PCR) is commonly used for pathogen detection in clinical and environmental samples. These sample matrices often contain inhibitors of PCR, which is a primary reason for sample processing; however, the purification process is highly inefficient, becoming unacceptable at lower signature concentrations. One potential solution is direct PCR assessment without sample processing. Here, we evaluated nine inhibitor-resistant PCR reagents for direct detection of Francisella tularensis in seven different clinical and environmental samples using an established real-time PCR assay to assess ability to overcome PCR inhibition. While several of these reagents were designed for standard PCR, the described inhibitor resistant properties (ex. Omni Klentaq can amplify target DNA samples of up to 20% whole blood or soil) led to our evaluation with real-time PCR. A preliminary limit of detection (LOD) was determined for each chemistry in whole blood and buffer, and LODs (20 replicates) were determined for the top five chemistries in each matrix (buffer, whole blood, sputum, stool, swab, soil, and sand). Not surprisingly, no single chemistry performed the best across all of the different matrices evaluated. For instance, Phusion Blood Direct PCR Kit, Phire Hot Start DNA polymerase, and Phire Hot Start DNA polymerase with STR Boost performed best for direct detection in whole blood while Phire Hot Start DNA polymerase with STR Boost were the only reagents to yield an LOD in the femtogram range for soil. Although not the best performer across all matrices, KAPA Blood PCR kit produced the most consistent results among the various conditions assessed. Overall, while these inhibitor resistant reagents show promise for direct amplification of complex samples by real-time PCR, the amount of template required for detection would not be in a clinically relevant range for most matrices.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据