4.6 Article

Postoperative Quantitative Assessment of Reconstructive Tissue Status in a Cutaneous Flap Model Using Spatial Frequency Domain Imaging

期刊

PLASTIC AND RECONSTRUCTIVE SURGERY
卷 127, 期 1, 页码 117-130

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/PRS.0b013e3181f959cc

关键词

-

类别

资金

  1. National Institutes of Health [1R03EB009451-01]
  2. Laser and Medical Microbeam Program [5P-41RR01192]
  3. Air Force Office [FA9550-08-1-0384]
  4. Beckman Foundation
  5. NATIONAL CENTER FOR RESEARCH RESOURCES [P41RR001192] Funding Source: NIH RePORTER
  6. NATIONAL INSTITUTE OF BIOMEDICAL IMAGING AND BIOENGINEERING [R03EB009451] Funding Source: NIH RePORTER

向作者/读者索取更多资源

Background: The purpose of this study was to investigate the capabilities of a novel optical wide-field imaging technology known as spatial frequency domain imaging to quantitatively assess reconstructive tissue status. Methods: Twenty-two cutaneous pedicle flaps were created on 11 rats based on the inferior epigastric vessels. After baseline measurement, all flaps underwent vascular ischemia, induced by clamping the supporting vessels for 2 hours (either arteriovenous or selective venous occlusions); normal saline was injected into the control flap and hypertonic-hyperoncotic saline solution was injected into the experimental flap. Flaps were monitored for 2 hours after reperfusion. The spatial frequency domain imaging system was used for quantitative assessment of flap status over the duration of the experiment. Results: All flaps demonstrated a significant decline in oxyhemoglobin and tissue oxygen saturation in response to occlusion. Total hemoglobin and deoxyhemoglobin were increased markedly in the selective venous occlusion group. After reperfusion and the administration of solutions, oxyhemoglobin and tissue oxygen saturation in those flaps that survived gradually returned to baseline levels. However, flaps for which oxyhemoglobin and tissue oxygen saturation did not show any signs of recovery appeared to be compromised and eventually became necrotic within 24 to 48 hours in both occlusion groups. Conclusions: Spatial frequency domain imaging technology provides a quantitative, objective method of assessing tissue status. This study demonstrates the potential of this optical technology to assess tissue perfusion in a very precise and quantitative way, enabling wide-field visualization of physiologic parameters. The results of this study suggest that spatial frequency domain imaging may provide a means for prospectively identifying dysfunctional flaps well in advance of failure. (Plast. Reconstr. Surg. 127: 117, 2011.)

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据