Monte Carlo simulated correction factors for machine specific reference field dose calibration and output factor measurement using fixed and iris collimators on the CyberKnife system

期刊

PHYSICS IN MEDICINE AND BIOLOGY
卷 57, 期 12, 页码 3741-3758

出版社

IOP PUBLISHING LTD
DOI: 10.1088/0031-9155/57/12/3741

关键词

-

资金

  1. Accuray Inc.

向作者/读者索取更多资源

Monte Carlo (MC) simulation of dose to water and dose to detector has been used to calculate the correction factors needed for dose calibration and output factor measurements on the CyberKnife system. Reference field ionization chambers simulated were the PTW 30006, Exradin A12, and NE 2571 Farmer chambers, and small volume chambers PTW 31014 and 31010. Correction factors for Farmer chambers were found to be 0.7%-0.9% larger than those determined from TRS-398 due mainly to the dose gradient across the chamber cavity. For one microchamber where comparison was possible, the factor was 0.5% lower than TRS-398 which is consistent with previous MC simulations of flattening filter free Linacs. Output factor detectors simulated were diode models PTW 60008, 60012, 60017, 60018, Sun Nuclear edge detector, air-filled microchambers Exradin A16 and PTW 31014, and liquid-filled microchamber PTW 31018 microLion. Factors were generated for both fixed and iris collimators. The resulting correction factors differ from unity by up to + 11% for air-filled microchambers and -6% for diodes at the smallest field size (5 mm), and tend towards unity with increasing field size (correction factor magnitude <1% for all detectors at field sizes >15 mm). Output factor measurements performed using these detectors with fixed and iris collimators on two different CyberKnife systems showed initial differences between detectors of >15% at 5 mm field size. After correction the measurements on each unit agreed within similar to 1.5% at the smallest field size. This paper provides a complete set of correction factors needed to apply a new small field dosimetry formalism to both collimator types on the CyberKnife system using a range of commonly used detectors.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

Article Oncology

Unresectable Locally Advanced Pancreatic Cancer: A Multimodal Treatment Using Neoadjuvant Chemoradiotherapy (Gemcitabine Plus Stereotactic Radiosurgery) and Subsequent Surgical Exploration

Francesco Polistina, Giorgio Costantin, Franco Casamassima, Paolo Francescon, Rosabianca Guglielmi, Gino Panizzoni, Antonio Febbraro, Giovanni Ambrosino

ANNALS OF SURGICAL ONCOLOGY (2010)

Article Radiology, Nuclear Medicine & Medical Imaging

Application of a Monte Carlo-based method for total scatter factors of small beams to new solid state micro-detectors

Paolo Francescon, Stefania Cora, Carlo Cavedon, Paolo Scalchi

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS (2009)

Article Clinical Neurology

Early results of CyberKnife radiosurgery for arteriovenous malformations Clinical article

Federico Colombo, Carlo Cavedon, Leopoldo Casentini, Paolo Francescon, Francesco Causin, Vittore Pinna

JOURNAL OF NEUROSURGERY (2009)

Article Radiology, Nuclear Medicine & Medical Imaging

Total scatter factors of small beams: A multidetector and Monte Carlo study

Paolo Francescon, Stefania Cora, Carlo Cavedon

MEDICAL PHYSICS (2008)

Correction Radiology, Nuclear Medicine & Medical Imaging

Total scatter factors of small beams: A multidetector and Monte Carlo study (vol 35, pg 504, 2008)

Paolo Francescon, Stefania Cora, Carlo Cavedon

MEDICAL PHYSICS (2010)

Article Radiology, Nuclear Medicine & Medical Imaging

Direct tumor in vivo dosimetry in highly-conformal radiotherapy: A feasibility study of implantable MOSFETs for hypofractionated extracranial treatments using the Cyberknife® system

Paolo Scalchi, Roberto Righetto, Carlo Cavedon, Paolo Francescon, Federico Colombo

MEDICAL PHYSICS (2010)

Article Radiology, Nuclear Medicine & Medical Imaging

Calculation of kQclin,Qmsrfclin,fmsr for several small detectors and for two linear accelerators using Monte Carlo simulations

P. Francescon, S. Cora, N. Satariano

MEDICAL PHYSICS (2011)

Article Radiology, Nuclear Medicine & Medical Imaging

Quality assurance of volumetric modulated arc therapy: Evaluation and comparison of different dosimetric systems

L. Masi, F. Casamassima, R. Doro, P. Francescon

MEDICAL PHYSICS (2011)

Article Radiology, Nuclear Medicine & Medical Imaging

Variation of kQclin, Qmsrfclin, fmsr for the small-field dosimetric parameters percentage depth dose, tissue-maximum ratio, and off-axis ratio

Paolo Francescon, Sam Beddar, Ninfa Satariano, Indra J. Das

MEDICAL PHYSICS (2014)

Article Clinical Neurology

CYBERKNIFE RADIOSURGERY FOR BENIGN MENINGIOMAS: SHORT-TERM RESULTS IN 199 PATIENTS

Federico Colombo, Leopoldo Casentini, Carlo Cavedon, Paolo Scalchi, Stefania Cora, Paolo Francescon

NEUROSURGERY (2009)

Article Engineering, Biomedical

Use of novel fibre-coupled radioluminescence and RADPOS dosimetry systems for total scatter factor measurements in small fields

N. Ploquin, G. Kertzscher, E. Vandervoort, J. E. Cygler, C. E. Andersen, P. Francescon

PHYSICS IN MEDICINE AND BIOLOGY (2015)

Article Oncology

Chemoradiation treatment with gemcitabine plus stereotactic body radiotherapy for unresectable, non-metastatic, locally advanced hilar cholangiocarcinoma. Results of a five year experience

Francesco Antonio Polistina, Rosabianca Guglielmi, Cristina Baiocchi, Paolo Francescon, Paolo Scalchi, Antonio Febbraro, Giorgio Costantin, Giovanni Ambrosino

RADIOTHERAPY AND ONCOLOGY (2011)

Article Oncology

Image-guided Robotic Stereotactic Radiosurgery for Unresectable Liver Metastases: Preliminary Results

Giovanni Ambrosino, Francesco Polistina, Giorgio Costantin, Paolo Francescon, Rosabianca Guglielmi, Pierluigi Zanco, Franco Casamassima, Antonio Febbraro, Giorgio Gerunda, Franco Lumachi

ANTICANCER RESEARCH (2009)

暂无数据