4.5 Article

Calibrating a FDR sensor for soil moisture monitoring in a wetland in Central Kenya

期刊

PHYSICS AND CHEMISTRY OF THE EARTH
卷 66, 期 -, 页码 101-111

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.pce.2013.09.004

关键词

Inland valley; Wetland; Capacitance sensor; Calibration; Kenya; Soil moisture

资金

  1. Capacity Building for Integrated Watershed Management in Eastern Africa (IWMNet) through the 9th European Development Fund (EDF)
  2. Volkswagen Foundation, Hannover, Germany
  3. Kenya Agricultural Research Institute
  4. Department of Soil Surveys, Nairobi, Kenya
  5. Agricultural Research Institute Mlingano, Tanzania

向作者/读者索取更多资源

The recent transformation of wetlands into farmland in East Africa is accelerating due to growing food-demand, land shortages, and an increasing unpredictability of climatic conditions for crop production in uplands. However, the conversion of pristine wetlands into sites of production may alter hydrological attributes with negative effects on production potential. Particularly the amount and the dynamics of plant available soil moisture in the rooting zone of crops determine to a large extent the agricultural production potential of wetlands. Various methods exist to assess soil moisture dynamics with Frequency Domain Reflectometry (FDR) being among the most prominent. However, the suitability of FOR sensors for assessing plant available soil moisture has to date not been confirmed for wetland soils in the region. We monitored the seasonal and spatial dynamics of water availability for crop growth in an inland valley wetland of the Kenyan highlands using a FOR sensor which was site-specifically calibrated. Access tubes were installed within different wetland use types and hydrological situations along valley transects and soil properties affecting soil moisture (organic C, texture, and bulk density) were investigated. There was little variation in soil attributes between physical positions in the valley, and also between topsoil and subsoil attributes with the exception of organic C contents. With a root mean squared error of 0.073 m(3)/m(3), the developed calibration function of the FDR sensor allows for reasonably accurate soil moisture prediction for both within-site comparisons and the monitoring of temporal soil moisture variations. Applying the calibration equation to a time series of profile probe readings over a period of one year illustrated not only the temporal variation of soil moisture, but also effects of land use. (C) 2013 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据