期刊
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY
卷 47, 期 -, 页码 64-72出版社
PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.tust.2014.12.010
关键词
Tunnel fire; CFD simulation; Small-scale model experiment; Critical velocity; Backlayering length
资金
- key program foundation of Ministry of Public Security, China [2011ZDYJCQXF019]
- Chongqing Graduate Student Research Innovation Project [CYB14031]
- 111Project [B13041]
This paper proposes two prediction models for backlayering length and critical velocity in metro tunnel fires, in which the characteristic hydraulic diameter of the tunnel (H) over bar was introduced to describe geometrical characteristic of the tunnel section. The dimensional analysis method was adopted to deduce the dimensional expressions of backlayering length and critical velocity. In addition, CFD simulations were conducted in nine tunnels with different cross sectional shapes by code of FDS 5.5. Meanwhile, a 1/10 scale model tunnel was built to provide a verification by carrying out small scale experiments. The experiment result shows a good agreement to the predicted values from the CFD simulation results. Then two prediction models of backlayering length and critical velocity were obtained from the dimensional expressions and the CFD simulation results. Moreover, the comparison of the prediction for the backlayering length indicates that the prediction model by Li et al. is lower than the CFD prediction model. And the critical velocity of the Wu & Barkar model are also underestimated. (C) 2015 Elsevier Ltd. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐