4.6 Article

Validation of a Simple Thyroid Cancer Dosimetry Model Based on the Fractional Whole-Body Retention at 48 Hours Post-Administration of 131I

期刊

THYROID
卷 25, 期 12, 页码 1347-1350

出版社

MARY ANN LIEBERT, INC
DOI: 10.1089/thy.2014.0616

关键词

-

向作者/读者索取更多资源

Background: Standard dosimetric methods to determine the maximum tolerated activity ( MTA) of 131 I for the treatment of metastatic, well- differentiated thyroid cancer ( DTC) are time- consuming and require complex analysis. As a result, reliable, accurate, and simplified methods are desirable. The objective of this study was to evaluate the validity of a simple regression dosimetry model. Method: Previously, the authors reported a bi- exponential model for estimating theMTAof 131 I for the treatment of metastatic DTC based on a limit of 2Gy to the blood. This model uses the patient's body surface area ( BSA) along with the fractional whole- body retention ( WBR) at 48 hours following oral administration of a diagnostic dosage of 131 I. A bi- exponential regression model was developed between the MTA normalized to the patient's BSA and the percent retention value at the 48- hour time point ( R): MTA( GBq)/ BSA( m 2) = ( 13.91 center dot e- 0.0387R + 42.33 center dot e- 0.8522R). In this study, the same model was applied to a different set of adult patients referred for dosimetry and possible 131 I treatment of DTC under conditions of thyroid hormone withdrawal or recombinant human thyrotropin ( rhTSH) stimulation. All patients ( n = 170; 96 female) referred to the authors' clinic for dosimetry and possible 131I treatment for metastatic DTC during the collection period were included in this study, apart from those undergoing renal dialysis. The MTA predicted ( MTA(p)) using the model described above was compared to the measured MTA ( MTAm), with statistical analysis performed using ProStat v4.5. Results: In this group, theMTAm ranged from2.3 to 41.1GBq. The linear correlation between theMTA(p) andMTA(m) was excellent ( r = 0.96), with an average deviation of only +/- 1.2%. However, to avoid overdosing a patient on the basis of the MTAp, a weighting factor (< 1.0) should be applied ( e. g., using a value of 0.7 would result in only one patient receiving a prescribed activity of 131 I that exceeded the MTAm [< 3%]). Conclusions: The % 48- hour WBR as determined by the bi- exponential function noted herein with reasonable restrictions has been validated as a reliable simplified dosimetry model.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据