期刊
OPTICS EXPRESS
卷 18, 期 18, 页码 18598-18614出版社
OPTICAL SOC AMER
DOI: 10.1364/OE.18.018598
关键词
-
类别
资金
- Division of Materials Sciences and Engineering, Office of Basic Energy Sciences, at the Department of Energy [DE-FG02-07ER46128]
- National Institute for General Medical Services at the National Institutes for Health [5R21EB6134]
The post-experiment processing of X-ray Diffraction Microscopy data is often time-consuming and difficult. This is mostly due to the fact that even if a preliminary result has been reconstructed, there is no definitive answer as to whether or not a better result with more consistently retrieved phases can still be obtained. We show here that the first step in data analysis, the assembly of two-dimensional diffraction patterns from a large set of raw diffraction data, is crucial to obtaining reconstructions of highest possible consistency. We have developed software that automates this process and results in consistently accurate diffraction patterns. We have furthermore derived some criteria of validity for a tool commonly used to assess the consistency of reconstructions, the phase retrieval transfer function, and suggest a modified version that has improved utility for judging reconstruction quality. (C) 2010 Optical Society of America
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐