4.6 Article

Extra-luminal detection of assumed colonic tumor site by near-infrared laparoscopy

期刊

出版社

SPRINGER
DOI: 10.1007/s00464-015-4669-9

关键词

Laparoscopic surgery; Colorectal cancer; Near-infrared (NIR) imaging; Nanoparticles

类别

资金

  1. New Energy and Industrial Technology Development Organization (NEDO) of Japan
  2. RIKEN (Molecular Systems research)
  3. National Cancer Center Research & Development Fund [25-A-8, 26-A-17]
  4. Accelerating Regulatory Science Initiative [H-24]
  5. Program for Development of Strategic Research Center in Private Universities - Ministry of Education, Culture, Sport, Science, and Technology, Japan (MEXT)
  6. Tokyo University of Science [S0901020]

向作者/读者索取更多资源

Localization of colorectal tumors during laparoscopic surgery is generally performed by tattooing into the submucosal layer of the colon. However, faint and diffuse tattoos may lead to difficulties in recognizing cancer sites, resulting in inappropriate resection of the colon. We previously demonstrated that yttrium oxide nanoparticles doped with the rare earth ions (ytterbium and erbium) (YNP) showed strong near-infrared (NIR) emission under NIR excitation (1550 nm emission with 980 nm excitation). NIR light can penetrate deep tissues. In this study, we developed an NIR laparoscopy imaging system and demonstrated its use for accurate resection of the colon in swine. The NIR laparoscopy system consisted of an NIR laparoscope, NIR excitation laser diode, and an NIR camera. Endo-clips coated with YNP (NIR clip), silicon rubber including YNP (NIR silicon mass), and YNP solution (NIR ink) were prepared as test NIR markers. We used a swine model to detect an assumed colon cancer site using NIR laparoscopy, followed by laparoscopic resection. The NIR markers were fixed at an assumed cancer site within the colon by endoscopy. An NIR laparoscope was then introduced into the abdominal cavity through a laparoscopy port. NIR emission from the markers in the swine colon was successfully recognized using the NIR laparoscopy imaging system. The position of the markers in the colon could be identified. Accurate resection of the colon was performed successfully by laparoscopic surgery under NIR fluorescence guidance. The presence of the NIR markers within the extirpated colon was confirmed, indicating resection of the appropriate site. NIR laparoscopic surgery is useful for colorectal cancer site recognition and accurate resection using laparoscopic surgery.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据