4.3 Article Proceedings Paper

Vacuum system for the SAMURAI spectrometer

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.nimb.2013.08.051

关键词

Vacuum chambers; Vacuum apparatus; Spectrometer

向作者/读者索取更多资源

The first commissioning experiment of the SAMURAI spectrometer and its beam line was performed in March, 2012. The vacuum system for the SAMURAI spectrometer includes its beam line and the SAMURAI vacuum chamber with the windows for detecting neutrons and charged particles. The window for neutrons was made of stainless steel with a thickness of 3 mm and was designed with a shape of partial cylinder to support itself against the atmospheric pressure. The window for charged particles was of the combination of Kevlar and Mylar with the thickness of 280 and 75 mu m, respectively. The pressure in the vacuum system was at a few Pa throughout the commissioning experiment. (C) 2013 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据