期刊
NEUROLOGIA MEDICO-CHIRURGICA
卷 48, 期 4, 页码 157-162出版社
JAPAN NEUROSURGICAL SOC
DOI: 10.2176/nmc.48.157
关键词
carotid plaque; functional imaging; high-resolution magnetic resonance imaging; macrophage; superparamagnetic particles of iron oxide
Macrophages and by-products are important in plaque destabilization in atherosclerosis. Ultra-small superparamagnetic particles of iron oxide (SPIO)-enhanced magnetic resonance (MR) imaging may be suitable for the detection of macrophages in atherosclerotic plaques. The present study investigated the potential of MR plaque imaging using SPIO in 10 patients scheduled for carotid endarterectomy before and 24-43 hours after administration of SPIO (fercarbotran, 0.016 ml/kg). Three-dimensional gradient recalled acquisition in the steady state (3D-GRASS) was used for detecting macrophages within plaques. Signal loss on the post-contrast 3D-GRASS images was found in 5 of 10 cases, and accumulation of SPIO particles in the vessel wall was confirmed in 4 of these 5 cases. Intracytoplasmic localization of SPIO particles within recruited macrophages was verified by double staining analysis. A correlation between MR plaque imaging using SPIO and localization of macrophages was demonstrated in 6 of 10 patients. This study indicates that MR plaque imaging using SPIO is a potential functional imaging tool to detect infiltration of macrophages in human atherosclerotic carotid plaque.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据