4.7 Article

Multi-graphical analysis of dynamic PET

期刊

NEUROIMAGE
卷 49, 期 4, 页码 2947-2957

出版社

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.neuroimage.2009.11.028

关键词

Gjedde-Patlak plot; Logan plot; Relative equilibrium; RE plot; PET

资金

  1. NIH [DA00412, MH078175, AA12839, AA012837, AA10158]

向作者/读者索取更多资源

In quantitative dynamic PET studies, graphical analysis methods including the Gjedde-Patlak plot, the Logan plot, and the relative equilibrium-based graphical plot (RE plot) (Zhou Y., Ye W., Brasic J.R., Crabb A.H., Hilton J., Wong D.F. 2009b. A consistent and efficient graphical analysis method to improve the quantification of reversible tracer binding in radioligand receptor dynamic PET studies. Neuroimage 44(3):661-670) are based on the theory of a compartmental model with assumptions on tissue tracer kinetics. If those assumptions are violated, then the resulting estimates may be biased. In this study, a multi-graphical analysis method was developed to characterize the non-relative equilibrium effects on the estimates of total distribution volume (DVT) from the RE plot. A novel bi-graphical analysis method using the RE plot with the Gjedde-Patlak plot (RE-GP plots) was proposed to estimate DVT for the quantification of reversible tracer kinetics that may not be at relative equilibrium states during PET study period. The RE-GP plots and the Logan plot were evaluated by 19 [C-11]WIN35,428 and 10 [C-11]MDL100,907 normal human dynamic PET studies with brain tissue tracer kinetics measured at both region of interest (ROI) and pixel levels. A 2-tissue compartment model (2TCM) was used to fit ROI time activity curves (TACs). By applying multi-graphical plots to the 2TCM fitted ROI TACs which were considered as the noise-free tracer kinetics, the estimates of DVT from the RE-GP plots, the Logan plot, and the 2TCM fitting were equal to each other. For the measured ROI TACs, there was no significant difference between the estimates of the DVT from the RE-GP plots and those from 2TCM fitting (p = 0.77), but the estimates of the DVT from the Logan plot were significantly (p<0.001) lower, 2.3% on average, than those from 2TCM fitting. There was a highly linear correlation between the ROI DVT from the parametric images (Y) and those from the ROI kinetics (X) by using the RE-GP plots (Y = 1.01X + 0.23, R-2 = 0.99). For the Logan plot, the ROI estimates from the parametric images were 13% to 83% lower than those from ROI kinetics. The computational time for generating parametric images was reduced by 69% on average by the RE-GP plots in contrast to the Logan plot. In conclusion, the bigraphical analysis method using the RE-GP plots was a reliable, robust and computationally efficient kinetic modeling approach to improve the quantification of dynamic PET. (C) 2009 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据