4.7 Article

EEG source analysis of epileptiform activity using a 1 mm anisotropic hexahedra finite element head model

期刊

NEUROIMAGE
卷 44, 期 2, 页码 399-410

出版社

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.neuroimage.2008.09.009

关键词

Presurgical epilepsy diagnosis; Surface- and intra-cranial EEG; Source analysis; Cerebrospinal fluid; Diffusion-tensor magnetic resonance imaging; Tissue conductivity anisotropy; Finite element method; Spatio-temporal dipole modeling; Goal function scan; Minimum norm least squares; Standardized low resolution electromagnetic; tomography

资金

  1. Deutsche Forschungsgemeinschaft [WO 1425/1-1, KN 588/2-1, JU 445/5-1]
  2. European Community
  3. CIMIT
  4. NSF ITR [0426558]
  5. NIHR [R03 CA126466, R01 RR021885, R01 GM074068, R01 EB008015]
  6. Direct For Computer & Info Scie & Enginr
  7. Division Of Computer and Network Systems [0426558] Funding Source: National Science Foundation

向作者/读者索取更多资源

The major goal of the evaluation in presurgical epilepsy diagnosis for medically intractable patients is the precise reconstruction of the epileptogenic foci, preferably with non-invasive methods. This paper evaluates whether surface electroencephalography (EEG) source analysis based on a 1 mm anisotropic finite element (FE) head model can provide additional guidance for presurgical epilepsy diagnosis and whether it is practically feasible in daily routine. A 1 mm hexahedra FE volume conductor model of the patient's head with special focus on accurately modeling the compartments skull, cerebrospinal fluid (CSF) and the anisotropic conducting brain tissues was constructed using non-linearly co-registered T1-, T2- and diffusion-tensormagnetic resonance imaging data. The electrodes of intra-cranial EEG (iEEG) measurements were extracted from a co-registered computed tomography image. Goal function scan (GFS), minimum norm least squares (MNLS), standardized low resolution electromagnetic tomography (sLORETA) and spatio-temporal current dipole modeling inverse methods were then applied to the peak of the averaged ictal discharges EEG data. MNLS and sLORETA pointed to a single center of activity. Moving and rotating single dipole fits resulted in an explained variance of more than 97%. The non-invasive EEG source analysis methods localized at the border of the lesion and at the border of the iEEG electrodes which mainly received ictal discharges. Source orientation was towards the epileptogenic tissue. For the reconstructed superficial source, brain conductivity anisotropy and the lesion conductivity had only a minor influence, whereas a correct modeling of the highly conducting CSF compartment and the anisotropic skull was found to be important. The proposed FE forward modeling approach strongly simplifies meshing and reduces run-time (37 ms for one forward computation in the model with 3.1 million unknowns), corroborating the practical feasibility of the approach. (C) 2008 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据