4.7 Article

hERG classification model based on a combination of support vector machine method and GRIND descriptors

期刊

MOLECULAR PHARMACEUTICS
卷 5, 期 1, 页码 117-127

出版社

AMER CHEMICAL SOC
DOI: 10.1021/mp700124e

关键词

human Ether-a-go-go Related Gene; support vector machine; GRIND descriptors; classification model

资金

  1. NIMH NIH HHS [U54 MH074425-01] Funding Source: Medline
  2. NATIONAL INSTITUTE OF MENTAL HEALTH [U54MH074425] Funding Source: NIH RePORTER

向作者/读者索取更多资源

The human Ether-a-go-go Related Gene (hERG) potassium channel is one of the major critical factors associated with QT interval prolongation and development of arrhythmia called Torsades de Pointes (TdP). It has become a growing concern of both regulatory agencies and pharmaceutical industries who invest substantial effort in the assessment of cardiac toxicity of drugs. The development of in silico tools to filter out potential hERG channel inhibitors in earlystages of the drug discovery process is of considerable interest. Here, we describe binary classification models based on a large and diverse library of 495 compounds. The models combine pharmacophore-based GRIND descriptors with a support vector machine (SVM) classifier in order to discriminate between hERG blockers and nonblockers. Our models were applied at different thresholds from 1 to 40 mu m and achieved an overall accuracy up to 94% with a Matthews coefficient correlation (MCC) of 0.86 (F-measure of 0.90 for blockers and 0.95 for nonblockers). The model at a 40 urn threshold showed the best performance and was validated internally (MCC of 0.40 and F-measure of 0.57 for blockers and 0.81 for nonblockers, using a leave-one-out cross-validation). On an external set of 66 compounds, 72% of the set was correctly predicted (F-measure of 0.86 and 0.34 for blockers and nonblockers, respectively). Finally, the model was also tested on a large set of hERG bioassay data recently made publicly available on PubChem (hftp://pubchem.ncbi.nlm.nih. gov/assay/assay.cgi?aid=376) to achieve about 73% accuracy (F-measure of 0.30 and 0.83 for blockers and nonblockers, respectively). Even if there is still some limitation in the assessment of hERG blockers, the performance of our model shows an improvement between 10% and 20% in the prediction of blockers compared to other methods, which can be useful in the filtering of potential hERG channel inhibitors.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据