4.7 Article

A graphene-based electrochemical sensor for sensitive and selective determination of hydroquinone

期刊

MICROCHIMICA ACTA
卷 176, 期 1-2, 页码 163-168

出版社

SPRINGER WIEN
DOI: 10.1007/s00604-011-0709-x

关键词

Electrochemical reduction; Graphene-modified electrode; Hydroquinone; Electrocatalytic; Selectivity

资金

  1. Natural Science Foundation of China (NSFC) [201105002]
  2. Anyang Technology Research Program [208]
  3. Anyang Normal University [308746]

向作者/读者索取更多资源

Graphene was prepared by electrochemical reduction of exfoliated graphite oxide at cathodic potentials, and used to fabricate a graphene-modified glassy carbon electrode (GCE) which was applied in a sensor for highly sensitive and selective voltammetric determination of hydroquinone (HQ). Compared to a bare (conventional) GCE, the redox peak current for HQ in pH 5.7 acetate buffer solution is significantly increased, indicating that graphene possesses electrocatalytic activity towards HQ. In addition, the peak-to-peak separation is significantly improved. The modified electrode enables sensing of HQ without interference by catechol or resorcinol. Under optimal conditions, the sensor exhibits excellent performance for detecting HQ with a detection limit of 0.8 mu M, a reproducibility of 2.5% (expressed as the RSD), and a recoveries from 98.4 to 101.2%.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据