Toward a better understanding of the gamma index: Investigation of parameters with a surface-based distance method

期刊

MEDICAL PHYSICS
卷 38, 期 12, 页码 6730-6741

出版社

AMER ASSOC PHYSICISTS MEDICINE AMER INST PHYSICS
DOI: 10.1118/1.3659707

关键词

gamma index; surface-based distance; IMRT QA; DTA; DD

资金

  1. National Institutes of Health through MD Anderson's Cancer Center [CA016672]

向作者/读者索取更多资源

Purpose: The purpose of this work was to clarify the interactions between the parameters used in the gamma index with the surface-based distance method, which itself can be viewed as a generalized version of the gamma index. The examined parameters included the distance to agreement (DTA)/dose difference (DD) criteria, the percentage used as a passing criterion, and the passing percentage for given DTA/DD criteria. The specific aims of our work were (1) to understand the relationships between the parameters used in the gamma index, (2) to determine the detection limit, or the minimum detectable error, of the gamma index with a given set of parameters, and (3) to establish a procedure to determine parameters that are consistent with the capacity of an IMRT QA system. Methods: The surface-based distance technique with dose gradient factor was derived, and then the relationship between surface-based distance and gamma index was established. The dose gradient factor for plans and measurements of 10 IMRT patients, 10 spine stereotactic radiosurgery (SRS) patients, and 3 Radiological Physics Center (RPC) head and neck phantom were calculated and evaluated. The detection limits of the surface-based distance and gamma index methods were examined by introducing known shifts to the 10 IMRT plans. Results: The means of the dose gradient factors were 0.434 mm/% and 0.956 mm/% for the SRS and IMRT plans, respectively. Key quantities (including the mean and 90th and 99th percentiles of the distance distribution) of the surface-based distance distribution between two dose distributions were linearly proportional to the actual shifts. However, the passing percentage of the gamma index for a given set of DTA/DD criteria was not associated with the actual shift. For IMRT, using the standard quality assurance criteria of 3 mm/3% DTA/DD and a 90% passing rate, we found that the detection limit of the gamma index in terms of global shift was 4.07 mm/4.07 % without noise. Conclusions: Surface-based distance is a direct measure of the difference between two dose distributions and can be used to evaluate or determine parameters for use in calculating the gamma index. The dose gradient factor represents the weighting between spatial and dose shift and should be determined before DTA/DD criteria are set. The authors also present a procedure to determine gamma index parameters from measurements. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3659707]

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据