A fast-time-response extreme ultraviolet spectrometer for measurement of impurity line emissions in the Experimental Advanced Superconducting Tokamak

期刊

REVIEW OF SCIENTIFIC INSTRUMENTS
卷 86, 期 12, 页码 -

出版社

AMER INST PHYSICS
DOI: 10.1063/1.4937723

关键词

-

资金

  1. National Magnetic Confinement Fusion Science Program of China [2014GB124006, 2013GB105003, 2015GB101000]
  2. National Natural Science Foundation of China [11575244, 11105181, 11305207]
  3. JSPS-NRF-NSFC A3 Foresight Program in the field of Plasma Physics (NSFC) [11261140328]
  4. JSPS-NRF-NSFC A3 Foresight Program in the field of Plasma Physics (NRF) [2012K2A2A6000443]
  5. Grants-in-Aid for Scientific Research [23340183] Funding Source: KAKEN

向作者/读者索取更多资源

A flat-field extreme ultraviolet (EUV) spectrometer working in the 20-500 angstrom wavelength range with fast time response has been newly developed to measure line emissions from highly ionized tungsten in the Experimental Advanced Superconducting Tokamak (EAST) with a tungsten divertor, while the monitoring of light and medium impurities is also an aim in the present development. A flat-field focal plane for spectral image detection is made by a laminar-type varied-line-spacing concave holographic grating with an angle of incidence of 87 degrees. A back-illuminated charge-coupled device (CCD) with a total size of 26.6 x 6.6 mm(2) and pixel numbers of 1024 x 255 (26 x 26 mu m(2)/pixel) is used for recording the focal image of spectral lines. An excellent spectral resolution of Delta lambda(0) = 3-4 pixels, where Delta lambda(0) is defined as full width at the foot position of a spectral line, is obtained at the 80-400 angstrom wavelength range after careful adjustment of the grating and CCD positions. The high signal readout rate of the CCD can improve the temporal resolution of time-resolved spectra when the CCD is operated in the full vertical binning mode. It is usually operated at 5 ms per frame. If the vertical size of the CCD is reduced with a narrow slit, the time response becomes faster. The high-time response in the spectral measurement therefore makes possible a variety of spectroscopic studies, e.g., impurity behavior in long pulse discharges with edge-localized mode bursts. An absolute intensity calibration of the EUV spectrometer is also carried out with a technique using the EUV bremsstrahlung continuum at 20-150 angstrom for quantitative data analysis. Thus, the high-time resolution tungsten spectra have been successfully observed with good spectral resolution using the present EUV spectrometer system. Typical tungsten spectra in the EUV wavelength range observed from EAST discharges are presented with absolute intensity and spectral identification. (C) 2015 AIP Publishing LLC.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据