4.3 Article

Liquid crystal-based biosensors using a strong polyelectrolyte-containing block copolymer, poly(4-cyanobiphenyl-4'-oxyundecylacrylate)-b-poly(sodium styrene sulfonate)

期刊

MACROMOLECULAR RESEARCH
卷 22, 期 8, 页码 888-894

出版社

POLYMER SOC KOREA
DOI: 10.1007/s13233-014-2112-z

关键词

strong anionic polyelectrolyte; poly(4-cyanobiphenyl-4 '-oxyundecylacrylate)-b-poly(sodium styrene sulfonate); monolayer; protein; reversible addition-fragmentation polymerization; biosensor

资金

  1. National Research Foundation of Korea [NRF-2011-0020264]

向作者/读者索取更多资源

The interface between a nematic liquid crystal phase, 4-cyano-4'-pentylbiphenyl (5CB) and water was examined for protein detection by monitoring the formation of a complex between sodium polystyrene sulfonate (PSSNa) and a positively charged biological species on the 5CB in a transmission electron microscopy (TEM) grid cell coated with a strong anionic polyelectrolyte-containing block copolymer, LCP-b-PSSNa (LCP:poly(4-cyanobiphenyl-4'-oxyundecylacrylate)). This block copolymer was successfully synthesized by reversible addition-fragmentation chain transfer polymerization. A monolayer of LCP-b-PSSNa in a Langmuir Blodgett trough (in which PSSNa and LCP were located in and above water, respectively, in the TEM grid cell) was transferred to the 5CB/water interface in the 5CB-filled TEM grid that was already placed on octadecyltrichlorosilane-coated glass. Model proteins such as bovine serum albumin (BSA), hemoglobin (Hb), alpha chymotrypsinogen-A (ChTg), and lysozyme (LYZ) having different isoelectric points (pIs) were tested for non-specific protein detection. When the protein solutions were injected into the TEM grid cell, the initial homeotropic orientation of 5CB in the TEM grid cell changed to a planar one below the pIs of the proteins due to electrostatic interactions between PSSNa (- charge) and the proteins (+ charge); this did not occur above the pIs of the tested proteins. The minimum concentrations at which the homeotropic to planar configurational changes (H-P changes) occurred were 0.02, 0.04, 0.04, and 0.08 wt% for BSA, Hb, ChTg, and LYZ, respectively. Therefore, the positively charged biomaterials were visually detected at the PSSNa-coated LC/water interface during an H-P change by using polarized optical microscopy under crossed polarizers. This simple set-up for non-specific biomaterial detection paves a way for the development of efficient and excellent quality biosensors.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据