4.3 Article

The efficacy of the inorganic copper-based biocide CuWB50 is compromised by hard water

期刊

LETTERS IN APPLIED MICROBIOLOGY
卷 46, 期 6, 页码 655-660

出版社

WILEY
DOI: 10.1111/j.1472-765X.2008.02369.x

关键词

biocide; copper; decontamination; intensive care unit; microfibre

资金

  1. Department of Health Funding Source: Medline

向作者/读者索取更多资源

Aims: We sought to explain the unexpected failure of the inorganic copper-based biocide CuWB50 to effectively decontaminate microfibre cleaning cloths that became contaminated with Acinetobacter lwoffii. Methods and Results: CuWB50 was diluted using distilled water or tap water obtained from two different ICUs. Microtitre plate assays were used to determine the minimum inhibitory concentration (MIC) for the implicated A. lwoffii. pH and oxidation-reduction potential (ORP) tests were performed and representative water samples were chemically analysed. When diluted in distilled water, the CuWB50 MIC for A. lwoffii was 9 mg l(-1) but in tap water from each ICU it was 37 and 75 mg l(-1) at hardness levels of 246 and 296 mg CaCO3 l(-1) respectively. CuWB50-distilled water solutions consistently had a lower pH and higher ORP than CuWB50-tap water solutions. Conclusions: Hard water adversely affects the biocidal efficacy of CuWB50. Significance and Impact of the Study: Unintentional environmental contamination is a risk when using wet microfibre cloths. This occurred when cloths were stored in CuWB50 overnight combined with the unintentional but erroneous use of tap water. This study emphasizes the need for clearly documented cleaning protocols embedded within a culture of adequate training and constant supervision of cleaning staff.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据